neurology · Other

Evaluation of Submandibular Gland Biopsies With Real-Time Quaking-Induced Conversion in Clinical Parkinson Disease.

Jürgens-Wemheuer Wiebke M WM, Martens Daniel D, Nessis Leja L, Kulas Phillip P, Pillong Lukas L, Rosar Florian F et al.
Neurology · Dec 8, 2026 · PMID 43013791 · DOI 10.1212/WNL.0000000000218704

Abstract (English)

BACKGROUND AND OBJECTIVES: The definite diagnosis of Parkinson disease (PD) is usually made by the detection of α-synuclein aggregates in the brain postmortem with the rare exception of some genetic forms. Traces of α-synuclein aggregates in extracerebral tissue biopsies may serve as an appropriate biomarker to confirm a clinical diagnosis in vivo. We set out to determine whether the detection of α-synuclein aggregates in submandibular gland biopsies is an effective means for diagnosing patients with PD. METHODS: In this prospective study, we consecutively acquired and examined submandibular gland biopsies from patients with clinical PD in neurologic care and controls who underwent surgical procedures on the submandibular gland for different reasons. Our index method was the detection of α-synuclein aggregates using the real-time quaking-induced conversion (RT-QuIC) in fresh-frozen tissue. We compared the results with immunohistochemical α-synuclein aggregate detection and paraffin-embedded tissue blot (PET-blot) as reference methods in formalin-fixed tissue from the same biopsy. RESULTS: The study population included 25 patients with clinical PD (mean age 67.3 ± 9.3 years, 64% male, 36% female) and 25 age-matched controls (mean age 64.6 ± 8.6 years, 48% male, 52% female). The RT-QuIC assay detected α-synuclein aggregates in submandibular gland biopsies (n = 41) with a sensitivity of 81.8%, which increased to 90% after a clinical follow-up, and a specificity of 100%, thus providing an accuracy of 90.2% (95% CI 76.6%-96.4%) and 95.1% (95% CI 82.9%-98.7%), respectively. The PET-blot with mAb5C12 (n = 49) confirmed 50% of the RT-QuIC positives and offered a sensitivity of 45.8% (50% after clinical follow-up) and a specificity of 100%. Immunohistochemical detection (n = 48) using the same antibody confirmed 28% of the RT-QuIC positives but found 2 of the controls to be positive and therefore provided a sensitivity of 26.1% (28.6% after clinical follow-up) and a specificity of 92%. DISCUSSION: With a sensitivity of more than 80%, which is comparable with the clinical diagnosis when neuropathologic examination serves as gold standard, the RT-QuIC assay on salivary gland biopsies may serve as a valuable instrument to improve the diagnosis of PD. Further validation is necessary to substantiate these findings in larger-scale investigations.

Read on PubMed

สรุปภาษาไทย · Thai PICO Summary

Population (ตัวอย่าง)

ผู้ป่วยผู้ใหญ่ที่ได้รับการวินิจฉัยตามเกณฑ์มาตรฐาน …

สรุปภาษาไทย PICO ฉบับเต็ม สำหรับแพทย์ที่ยืนยันตัวตน — Sign up free
Sign up free